Igwe ntụ oyi dị n'ahịrị nkenke (usoro njikọ-thunder)

Nkọwa dị mkpirikpi:


Nkọwa ngwaahịa

FAQ

Njikọ-Thunder usoro in-ahiri nkenke ikuku ntụ oyi, na uru nke ịzọpụta ike, nchekwa na ntụkwasị obi njikwa, kọmpat Ọdịdị, elu usoro, ultra elu SHR na jụrụ nso na okpomọkụ isi iyi, n'ụzọ zuru ezu na-egbo mkpa jụrụ nke data center na elu. okpomọkụ njupụta.

Atụmatụ
1. Oke arụmọrụ na nchekwa ike
-Ezigbo kacha mma nke ihe ntụgharị ọkụ na ikuku ikuku site na CFD, yana arụmọrụ dị elu na obere nguzogide maka okpomọkụ na mbufe oke.
-Ultra elu ezi uche okpomọkụ ruru na-ezere ọnwụ kpatara ugboro ugboro iru mmiri na dehumidification
-Jiri elu-arụ ọrụ nke ọma na eco refrigerant R410A dị ka ọkọlọtọ
valvụ mgbasawanye eletrọnịkị dị elu
-Elu-arụ ọrụ nke ọma inverter compressor, nwere ọgụgụ isi jụrụ ikike mgbanwe
-Onye na-agba ọsọ na-enweghị nkwụsị
-Elu-nkenke PID Damper (ụdị mmiri oyi oyi)
-Spepless Speed ​​Scythe Ụdị jụrụ oyi
-Amụma njikwa kacha mma na-eme ka ike nchekwa kachasị nke nkeji

2. Elu ntụkwasị obi
-365 ụbọchị 7 × 24- hour adịghị akwụsị akwụsị ime imewe
-A na-anwale akụkụ niile ma nyochaa nke ọma
- Nchekwa na ntụkwasị obi PTC ọkụ eletrik
-Condensing mgbapụta na njikwa ọkwa mmiri yana nchebe oyiri a pụrụ ịdabere na ya nke mgbochi ujo na atụmatụ mgbochi mmanụ.
-Nchekwa nche zuru oke na nyocha akpaaka
- N'ikwekọ na ụkpụrụ nchekwa, EMC na CE asambodo

3. Njikwa ọgụgụ isi
-Mmepụta ihu igwe mmadụ-igwe
- Nnukwu ihuenyo mmetụ LCD
-Humanized imewe na otu-emetụ ọrụ
-Asụsụ Interface nhọrọ (Bekee/Chinese)
- Ngosipụta ọnọdụ ọrụ (gụnyere refrigeration, kpo oku, dehumidification, iru mmiri)
-A na-egosipụta onyonyo agba nke akụrụngwa
- Trendchart gosipụtara data okpomọkụ na iru mmiri
- Chekwaa ma gosipụta ndekọ njikere 400 kacha
- Nchedo anya
- Nchekwa akpaaka zuru oke yana ọrụ njikere
-Nchọpụta akpaaka
-Nleta oke na ngbanwe zuru oke
- Malitegharịa ekwentị na akpaghị aka
-Nchọpụta ntapu mmiri
-ọkụ na anwụrụ ọkụ mkpu
-echebe ọkụ
- Njikwa ọrụ otu
-Standard RS485 nkwurịta okwu interface na nlereanya- ụgbọ ala nkwurịta okwu protocol
- njikwa ọrụ otu maka nkeji 32 kachasị
-Ndabere data, ntụgharị na cascade iji zere ịgba ọsọ ọsọ
-Nleba anya mgbake ọdachi
-LonWORK, BACNET ma ọ bụ Ethernet protocol nhọrọ

4. Usoro dị elu
- ISO njikwa mma na mmepụta ihe siri ike (TPS)
- Usoro nrụpụta maka akụrụngwa IT
-Kabinet ojii dị mma ma dị mma dabara data center nke ọma
-Ere ike dị elu dabara adaba maka njem ụgbọ mmiri, ala na ikuku

5. Nlekọta dị mfe
-Compressor oriri / iyuzucha ọdụ ụgbọ mmiri na-anabata ROTAL- LOCK threaded nkwonkwo maka mfe mmezi
-Fan na moto kpọmkwem-ejikọta ọnụ imewe, ọ dịghị mkpa ịgbanwe belt
-Dabara adaba n'ihu na azụ ụzọ nnweta ụzọ dị

6. Nchekwa ụlọ
-Cabinet nwere akụkụ ọkọlọtọ nwere nhazi kọmpat na modular
- Chekwaa ebe nrụnye na oghere nrụzi ka o kwere mee

7. Na-adaba na gburugburu ngwa ngwa dị iche iche
-Ọdabara maka ọrụ ọnọdụ okpomọkụ nso - 40 ~ +55 ℃
- ogologo-njikọ ọkpọkọ na elu-dobe imewe
-Eco chepụta na nrubeisi na ROHS, REACH na wdg.
-CE, UL na TUV asambodo nwetara
-Nzaghachi ngwa ngwa ahịa na ngwọta ahaziri agbanwe agbanwe

Ngwa
Ebe data modulu
Ebe data akpa
Ebe data dị oke ọkụ


  • Nke gara aga:
  • Osote:

  • Zitere anyị ozi gị:

    Dee ozi gị ebe a ziga anyị ya
    Hapụ Ozi Gị